Subject
[Stage]: Other. Please describe below.
Describe the bug
After running analyze_power_grid on both VDD and VSS, I pulled up the IR Drop heatmap and it complains:
[INFO PSM-0040] All shapes on net VDD are connected.
########## IR report #################
Net : VDD
Corner : default
Total power : 7.55e-04 W
Supply voltage : 7.70e-01 V
Worstcase voltage: 7.66e-01 V
Average voltage : 7.68e-01 V
Average IR drop : 1.63e-03 V
Worstcase IR drop: 3.86e-03 V
Percentage drop : 0.50 %
######################################
[INFO PSM-0040] All shapes on net VSS are connected.
########## IR report #################
Net : VSS
Corner : default
Total power : 7.55e-04 W
Supply voltage : 0.00e+00 V
Worstcase voltage: 3.76e-03 V
Average voltage : 1.70e-03 V
Average IR drop : 1.70e-03 V
Worstcase IR drop: 3.76e-03 V
Percentage drop : 0.49 %
######################################
[WARNING GUI-0066] Heat map "IR Drop" has not been populated with data.
and then displays what looks like a valid IR Drop heatmap.
What data is missing?
Expected Behavior
If there's no data, then a heatmap shouldn't be displayed, right?
If there's data, then why warn?
Environment
orfs git commit tag: ceb386103ac58f0f6fe250e7de65897c4cb865f6
To Reproduce
mkissue tarball: https://drive.google.com/file/d/1of18W5aayLPTp6QjetSJF7DmfgojbjNJ/view?usp=drive_link
Relevant log output
Screenshots
No response
Additional Context
No response
Subject
[Stage]: Other. Please describe below.
Describe the bug
After running analyze_power_grid on both VDD and VSS, I pulled up the IR Drop heatmap and it complains:
and then displays what looks like a valid IR Drop heatmap.
What data is missing?
Expected Behavior
If there's no data, then a heatmap shouldn't be displayed, right?
If there's data, then why warn?
Environment
To Reproduce
mkissue tarball: https://drive.google.com/file/d/1of18W5aayLPTp6QjetSJF7DmfgojbjNJ/view?usp=drive_link
Relevant log output
Screenshots
No response
Additional Context
No response