First I just want to offer a huge thanks to all who have contributed to this excellent documentation. I managed to create a working (prototype) implementation for controlling my heatpump in a single weekend by simply following this specification (and some other resources, mainly pymitsubishi, since I communicate via the wifi module).

But there was one thing that tripped me for a bit, namely how the "Update Flags" (bytes 1-2 in command 0x01. Example: to turn on the power, the page says the flags should be set to 0x0001, but the actual packet needs to look like

[FC.41.01.30.10] 01.**01.00**.01.00.00.00.00.00.00.00.00.00.00.00.00 7B

This could be correct if the flags are written little-endian, but all other multi-byte values (e.g., the error code in Get Error State seems to be big-endian, so it gets confusing to mix the two. Is this a mistake in the documentation, or have I misunderstood something?

I can provide a PR to fix it if it turns out to be a mistake.