MATLAB-based framework for converting BCI2000 ".dat" recordings into BIDS-compatible electrophysiology datasets.
This project provides a MATLAB-based framework for converting BCI2000 .dat
recordings into BIDS-compatible electrophysiology datasets.
The architecture is divided into two layers:
-
GUI layer
- Selects input BCI2000 recordings.
- Selects a conversion profile.
- Collects BIDS entities such as subject, session, task, acquisition, and run.
- Selects the desired output signal format.
- Calls the
BCI2000_dataclass for each selected recording.
-
Conversion layer (
BCI2000_data)- Loads one BCI2000
.datrecording. - Loads a JSON conversion profile.
- Applies metadata mappings.
- Loads and activates optional extension profiles.
- Applies profile-defined preprocessing.
- Adds auxiliary BCI2000 states as channels.
- Converts selected states to
events.tsv. - Generates BIDS JSON sidecars.
- Handles stimulation metadata.
- Writes custom stimulation-parameter JSON files when applicable.
- Dispatches signal writing to format-specific external conversion functions.
- Loads one BCI2000
The BCI2000_data class represents a single BCI2000 recording.
BCI2000_data.m Main MATLAB class representing one BCI2000 recording and its conversion state.
BCI2000_to_BIDS_GUI.mlapp / BCI2000_to_BIDS_GUI.m App Designer front end for selecting recordings and BIDS conversion settings.
dat2mef.m
External MEF3 signal writer using the mef3io package.
dat2edf.m External EDF writer using MATLAB EDF functionality.
parseBCI2000_parameters_values.m Helper used to parse BCI2000 matrix/list parameters into MATLAB tables.
conversionProfiles/ Directory containing base conversion profiles and optional extension profiles.
A single recording can be converted directly without using the GUI:
data = BCI2000_data( ...
"/path/to/recording.dat", ...
"/path/to/conversionProfiles/CorTecBIC_profile.json");
data.setBIDSContext("c01", "closedLoop", "motor");
data.convert2BIDS( ...
"/output/sub-c01/ses-closedLoop/ieeg/" + ...
"sub-c01_ses-closedLoop_task-motor_ieeg.mefd");
The class handles loading, profile application, preprocessing, auxiliary states, events, sidecars, stimulation metadata, and format dispatch.
The BCI2000-to-BIDS converter relies on the following external software:
- BCI2000 MATLAB MEX Files – Required for reading and writing BCI2000 .dat files (load_bcidat, save_bcidat, read_bcidate).
- MEF3IO – Required for exporting recordings to the Multiscale Electrophysiology Format (MEF3).
- BIDS Validator (recommended) – Recommended for validating the generated BIDS dataset prior to sharing or publication.
- MATLAB Signal Processing Toolbox – Required only for EDF export (edfwrite, edfheader).
Conversion profiles are JSON files that describe how BCI2000 parameters and states should be interpreted for a particular device, source module, task, or optional BCI2000 extension.
The goal is to keep device-specific logic in JSON whenever possible and keep
BCI2000_data generic.
There are three main profile categories:
- Base conversion profiles
- Extension profiles
- Task/stimulation profiles
A base profile defines the main acquisition hardware and the canonical metadata that should be extracted from the BCI2000 file.
Examples:
BCI2000_Generic_profile.json
CorTecBIC_profile.json
gHIamp_profile.json
gHIamp_FunctionalData.json
gHIamp_Stimulation.json
A typical base profile contains:
{
"profileName": "gHIamp",
"profileVersion": "0.1.0",
"description": "...",
"modality": "iEEG",
"metadata": {
"Device": { ... },
"Recording": { ... },
"Provenance": { ... }
},
"events": [ ... ],
"preprocessing": [ ... ],
"extensions": [ ... ],
"stimulation": { ... }
}
profileName Unique profile name.
profileVersion Version string for the profile. Increment this when mapping behavior changes.
description Human-readable description.
modality
BIDS modality currently used by the converter. Current intracranial profiles
generally use "iEEG".
The metadata field maps BCI2000 parameters into canonical metadata used by
BCI2000_data.
Example:
"SamplingFrequency": {
"source": "parameter",
"path": "SamplingRate",
"aliases": ["Source.SamplingRate"],
"required": true,
"transform": "parseNumeric"
}
The corresponding output becomes:
data.Metadata.Recording.SamplingFrequency
source
Defines where the value comes from. Common values are "parameter" and
"constant".
path Name/path of the BCI2000 parameter.
aliases Optional alternative parameter paths to try when the primary path is not available.
required If true, failure to resolve the field is treated as a validation error.
default Fallback value when no source parameter is available.
value
Constant value used when "source": "constant".
transform Transformation applied after extracting the value.
valueIndex
Optional matrix/cell index used for BCI2000 parameters whose Value field
is a matrix.
Example:
"SourceModule": {
"source": "parameter",
"path": "SignalSourceFilterChain",
"valueIndex": [2, 1],
"default": "gHIampADC",
"transform": "toString"
}
parseNumeric Converts common BCI2000 numeric representations into MATLAB doubles.
toString Converts the resolved value into a MATLAB string.
Datetime
Converts a BCI2000 date/time field such as StorageTime into MATLAB
datetime.
joinStrings Joins a list/matrix of strings into a single readable value.
extractUnitsFromGain
Extracts physical units from SourceChGain entries and normalizes them for
channel metadata.
Additional transforms may be added to BCI2000_data when required by future
devices.
Profiles may define nested metadata structures.
Example:
"HardwareFilters": {
"BandPassFilter": {
"Enabled": {
"source": "parameter",
"path": "FilterEnabled",
"transform": "parseNumeric"
},
"HighPassCutoffHz": {
"source": "parameter",
"path": "FilterHighPass",
"transform": "parseNumeric"
}
}
}
This becomes:
data.Metadata.Recording.HardwareFilters.BandPassFilter.Enabled
data.Metadata.Recording.HardwareFilters.BandPassFilter.HighPassCutoffHz
BCI2000 states can be preserved as additional auxiliary channels in the output signal file.
Example:
{
"name": "ImplantLostSample",
"source": "state",
"path": "ImplantLostSample",
"includeAsAuxiliarySignal": true,
"includeInEvents": false,
"decoder": "none",
"units": "n/a"
}
Important fields:
name Output channel/event name.
source
Should be "state" for BCI2000 states.
path
State name in data.States.
includeAsAuxiliarySignal If true, the state is appended to the converted signal as an additional channel.
includeInEvents If true, the state is also interpreted into BIDS events.
decoder Defines the event-decoding strategy.
units Physical units for the auxiliary channel.
The generic BCI2000 profile supports:
"events": "all"
This expands every available BCI2000 state into an auxiliary channel with:
includeAsAuxiliarySignal = true
includeInEvents = false
Some BCI2000 states store packed numeric values and require a state-specific transform before export.
Only states explicitly requesting a transform are transformed.
toDouble Conventional MATLAB numeric conversion:
double(values)
typecastSingle Reinterprets packed bytes as IEEE-754 single precision:
typecast(values, "single")
The result is then converted to MATLAB double for downstream processing.
typecastDouble Reinterprets packed bytes as IEEE-754 double precision.
XsensMTwDegrees Recovers Xsens MTw orientation values using:
(state - 2^31) / DataPrescaler
Extension profiles are optional JSON profiles that add states, transforms, metadata, or stimulation behavior only when a BCI2000 feature is active.
Examples:
XsensMTwLogger.json
StimulusPresentationTask.json
gEstimFilter.json
CorTecBIC_OnlineProcessing.json
A base profile references extensions as:
"extensions": [
{"profile": "XsensMTwLogger.json"},
{"profile": "StimulusPresentationTask.json"}
]
Extension paths are resolved relative to the main profile file.
An extension may define an activation condition.
Numeric example:
"activation": {
"source": "parameter",
"path": "LogXsensMTw",
"equals": 1
}
String example:
"activation": {
"source": "parameter",
"path": "ApplicationFilterChain",
"equals": "StimulusPresentationTask"
}
Extension profiles should use "states" rather than the main profile's
top-level "events" array.
Example:
{
"profileName": "StimulusPresentationTask",
"profileVersion": "0.1.1",
"activation": {
"source": "parameter",
"path": "ApplicationFilterChain",
"equals": "StimulusPresentationTask"
},
"states": [
{
"name": "StimulusCode",
"source": "state",
"path": "StimulusCode",
"includeAsAuxiliarySignal": true,
"includeInEvents": true,
"decoder": "stateIntervals",
"units": "n/a"
}
]
}
Profiles may specify preprocessing operations that modify the signal used for export while preserving the original loaded signal.
The class maintains:
data.Signal
Original calibrated BCI2000 signal.
data.ProcessedSignal
Signal after profile-defined preprocessing. This is used for BIDS export.
Example: CorTec BIC packet-loss correction
"preprocessing": [
{
"function": "maskStateSamples",
"state": "ImplantLostSample",
"condition": "nonzero",
"target": "signal",
"replacement": "NaN"
}
]
This replaces samples identified by ImplantLostSample with NaN in
ProcessedSignal while leaving the original Signal and state vector intact.
States with "includeInEvents": true are converted into *_events.tsv.
For stateIntervals, contiguous non-zero periods are converted into rows with:
onset
duration
trial_type
value
sample
The accompanying *_events.json describes these columns.
The StimulusPresentationTask extension typically preserves task-related states
such as:
PresentationRequested
PresentationDisplayed
StimulusCode
StimulusBegin
PhaseInSequence
Electrical stimulation is represented separately from generic events.
The BIDS iEEG sidecar is populated with:
"ElectricalStimulation": true
when an active stimulation profile is enabled.
Actual stimulation periods are written to events.tsv using
electrical_stimulation_<label> columns.
The converter currently supports two stimulation configuration modes.
triggerTable
Used for systems such as CorTec Brain Interchange where a trigger-state value
selects a column from a BCI2000 stimulation-trigger table.
Example:
"stimulation": {
"enabled": true,
"mode": "triggerTable",
"eventState": "ImplantStimulation",
"triggerState": "StimulusCode",
"parametersPath": "parameters.StimulationPulses",
"triggersPath": "parameters.StimulationTriggers",
"triggerRow": 1,
"functionIDsRow": 2
}
parameterSet
Used for systems such as BCI2000 gEstimFilter, where stimulation configuration
is described by a collection of parameters.
Example:
"stimulation": {
"enabled": true,
"mode": "parameterSet",
"eventState": "EstimStimulus",
"triggerState": "StimulusCode",
"parameterPaths": [
"Magnitude",
"PhaseDuration",
"InterphaseDuration",
"NumberOfPulses",
"PulseFrequency"
]
}
When stimulation is enabled, the converter also writes a custom file:
<BIDS root>/stimuli/
sub-<label>[_ses-<label>]_task-<label>[_acq-<label>][_run-<index>]_stimParameters.json
This file is additional to the BIDS specification and preserves the complete BCI2000 stimulation configuration.
Complex BCI2000 matrix parameters are parsed using:
parseBCI2000_parameters_values.m
BCI2000_Generic_profile.json
Purpose: Device-agnostic conversion and export of all BCI2000 states as auxiliary channels.
CorTecBIC_profile.json
Purpose: CorTec Brain Interchange recordings.
Typical behavior: - Manufacturer/model metadata. - ImplantLostSample auxiliary state. - Lost-sample masking to NaN. - Optional Xsens extension. - Optional StimulusPresentationTask extension. - CorTec stimulation trigger-table handling.
gHIamp_profile.json
Purpose: g.tec g.HIamp recordings.
Typical behavior: - g.HIamp device metadata. - g.HIamp reference channels. - g.HIamp filter metadata. - Channel-unit extraction from SourceChGain.
gHIamp_FunctionalData.json
Purpose: g.HIamp functional/task recordings.
Typical behavior: - g.HIamp base metadata. - DigitalInput1 auxiliary state. - StimulusPresentationTask extension.
gHIamp_Stimulation.json
Purpose: g.HIamp recordings using gEstimFilter stimulation.
Typical behavior: - g.HIamp base metadata. - StimulusPresentationTask extension. - gEstimFilter extension. - gEstim stimulation parameters. - Electrical stimulation events.
-
Inspect one representative BCI2000
.datfile. -
Record relevant parameter names:
fieldnames(parameters) -
Record available states:
fieldnames(states) -
Determine:
- amplifier/source module;
- modality;
- sampling-rate parameter;
- channel-count parameter;
- channel units;
- reference configuration;
- hardware filters;
- task-related states;
- optional BCI2000 logger/filter modules;
- stimulation parameters, if applicable;
- device-specific preprocessing requirements.
-
Decide whether the new behavior belongs in:
- a base device profile;
- an extension profile;
- a task profile;
- a stimulation extension.
-
Reuse existing generic transforms and preprocessing functions whenever possible.
-
Only modify
BCI2000_datawhen the new profile requires behavior that cannot be expressed using the existing profile schema. -
Validate the resulting BIDS dataset with the BIDS Validator.
Use the following prompt together with the current BCI2000_data.m, relevant
existing profile examples, and documentation for the new BCI2000 device/module.
I am extending a MATLAB BCI2000-to-BIDS converter.
The converter uses BCI2000_data.m as a generalized conversion class and JSON
profiles to describe device-specific and task-specific behavior.
Please create a new conversion profile for:
<DEVICE / BCI2000 MODULE NAME>
BCI2000 documentation:
<DOCUMENTATION URL>
The recording modality is:
<iEEG / EEG / other>
Relevant BCI2000 parameters are:
<LIST PARAMETER NAMES OR PASTE parameter STRUCTURE EXAMPLES>
Relevant BCI2000 states are:
<LIST STATE NAMES>
The required behavior is:
- Manufacturer: <...>
- Model: <...>
- Sampling frequency parameter: <...>
- Channel-count parameter: <...>
- Channel units: <...>
- Reference parameter: <...>
- Hardware-filter parameters: <...>
- States to preserve as auxiliary channels: <...>
- States to convert to events: <...>
- Required state transforms: <...>
- Required preprocessing: <...>
- Stimulation enabled: <true/false>
- Stimulation event state: <...>
- Stimulation trigger state: <...>
- Stimulation parameter locations: <...>
- Optional BCI2000 extensions that should be activated: <...>
Please use the existing conversion-profile architecture rather than hard-coding
device-specific logic into BCI2000_data.
Requirements:
- Produce valid JSON.
- Use a base profile for the acquisition device and extension profiles for optional BCI2000 modules whenever appropriate.
- Use
"states"inside extension profiles. - Use
"events"in the main profile only for states belonging directly to that profile. - Reuse existing transforms where possible: parseNumeric toString Datetime joinStrings extractUnitsFromGain toDouble typecastSingle typecastDouble XsensMTwDegrees
- Use profile-defined preprocessing rather than device-specific MATLAB code when possible.
- For stimulation, use either
"mode": "triggerTable"or"mode": "parameterSet"depending on how the BCI2000 module stores stimulation configuration. - Preserve stimulation configuration in the custom
stimuli/*_stimParameters.jsonoutput when stimulation is enabled. - Identify any changes genuinely required in
BCI2000_data.m. - Do not introduce additional signal calibration if the BCI2000 data are
already loaded using
load_bcidat(..., '-calibrated'). - If a packed BCI2000 state requires reinterpretation, use
typecastonly for that explicitly specified state. - Clearly explain assumptions before implementing behavior that is not established by the BCI2000 documentation or supplied data.
Return: A. The complete JSON profile. B. Any required extension-profile JSON files. C. Only the MATLAB changes necessary to support the profile. D. A short explanation of how the profile maps BCI2000 data into BIDS.
Device-specific metadata should normally be expressed in JSON. Add MATLAB logic only when a genuinely new generic operation is required.
Signal, States, and Parameters should preserve the source recording.
Signal corrections should operate on ProcessedSignal.
When the BCI2000 loader is called with:
load_bcidat(..., "-calibrated")
the returned signal is already in physical units. Do not apply SourceChGain or SourceChOffset a second time.
Optional modules such as Xsens, StimulusPresentationTask, online processing, or gEstimFilter should be implemented as extension profiles instead of duplicating their logic across multiple base profiles.
Signal writers should accept one physical unit per channel so neural channels and auxiliary channels can coexist correctly.
Example:
Ch1 uV
Ch2 uV
MTw1X degrees
EstimCurrent uA
NormalizerOutput a.u.
The converter should maintain validation messages rather than silently ignoring missing required metadata. After conversion, validate the resulting dataset with the official BIDS Validator.
- BrainVision signal export is not yet fully implemented.
- Additional BCI2000 modules may require new generic transforms.
- More event decoders may be needed for states that are not naturally represented as contiguous non-zero intervals.
- Profile inheritance could further reduce duplication between closely related base profiles.
- Automated BIDS dataset-level files such as
dataset_description.json,participants.tsv, andscans.tsvmay be expanded further depending on the intended release workflow.