Loads one BALTECH reader configuration (.bec) onto many Ethernet readers in parallel.
The readers are listed in a CSV file (IP address, optionally with port). Each reader is
updated over an encrypted BRP-over-TCP session that is authenticated with the transport
certificate package in certs/.
Run BulkEthernetConfigUploader-<version>-setup.exe. It installs for the current user
without administrator rights into %LOCALAPPDATA%\Programs\BulkEthernetConfigUploader and
adds a Start menu entry. The program folder also holds becu-cli.exe for scripts, the
certificate package in certs\, and after the first run reports\ and logs\.
Install uv once (installer from that page or winget install astral-sh.uv). Put the sources into a short path such as C:\BECU (the Python launcher
fails in folder paths longer than about 150 characters) and double-click Start.cmd. On
the first start uv downloads Python 3.13 and the packages, once per PC, and creates the
project environment .venv in the program folder; this needs internet access and about a
minute. Later starts take a few seconds. uv uses the Python 3.13 it manages itself; a
Python installed from python.org or the Microsoft Store is used only if uv cannot download.
In the window:
- Select the CSV file. A header line is detected and skipped automatically. Select the
column with the addresses (
a.b.c.dora.b.c.d:port). If the addresses carry no port, you can select a port column; without one, port 2939 is used. - Select the
.becconfiguration file. - The certificate package from
certs\is preselected; "Change..." selects another one. - Options: "Max. parallel readers" limits how many readers are in progress at the same time ("all" = no limit). "Start up to N readers per second" (default 10) limits the connection burst at the start; 1000 starts all readers nearly at once. "Automatic retries for temporary errors" repeats a reader, 5 seconds apart, when it is unreachable or busy, the connection is lost during the upload, or it does not answer after the reboot; a rejected certificate, access denied, a refused configuration or a wrong configuration after the reboot are not retried.
- "Command line for automation" shows the command line call that performs the same update with the current settings; "Copy" puts it on the clipboard. Use it in a script (see Command line below).
- "Estimated duration" is a rough figure for the whole update from the reader count, the start rate, the parallel limit and the configuration size; retries and errors are not included. Start. The counters show pending, handshaking, updating, rebooting, updated and errors. Readers that end with an error are listed; "Retry errors" runs all of them again.
Every run writes a report CSV to reports\ and a log to logs\becu.log in the program
folder.
Installed program: becu-cli.exe in the program folder. From the sources:
.venv\Scripts\python.exe -m becu.cli in the program folder, or uv run python -m becu.cli.
becu-cli.exe --csv readers.csv --config project.bec [options]
becu-cli.exe --address 192.168.1.10:2939 --config project.bec
becu-cli.exe --csv readers.csv --list-columns
Run with --help for all options. Columns are given as 0-based indices (--ip-column 1
is the second column); --list-columns shows them. The exit code is 0 when every reader
was updated, 1 when at least one reader ended with an error, 2 for a usage error. The GUI
field "Command line for automation" produces the exact call, for the installed program or
for the sources.
uv sync
uv run pytest
uv run inv --list
uv run inv installer # builds dist/BulkEthernetConfigUploader-<version>-setup.exe
inv installer bundles the GUI and the CLI with PyInstaller into dist/BulkEthernetConfigUploader/
(certificate package included) and wraps that folder with Inno Setup into the per-user installer.
Inno Setup must be installed on the build PC: winget install -e --id JRSoftware.InnoSetup.
A pushed tag vX.Y.Z that matches the version in pyproject.toml makes GitHub Actions build
the installer and attach it to the release of that tag (.github/workflows/installer.yml).
mock/ simulates Kofax Ethernet card readers on loopback addresses (BRP over TCP, PKI secure channel,
BEC upload, real timing). It generates its own test certificates in mock/test_pki/.
uv run python -m mock --count 1800 --bec project.bec --faults uptodate=100,unreachable=10,busy=5,locked=5,denied=3,conflict=3,drop=5,mismatch=2,slow=20
uv run python -m becu.cli --csv mock/readers.csv --config project.bec --cert mock/test_pki/PKI_AUTH_BECU_TEST.zip --start-rate 50 --auto-confirm
mock/expected.csv lists the state and error class the tool should report per reader.
--time-scale 0 removes all simulated delays. Measured with 1800 readers, real timing and
50 starts per second: 143 s for the whole run, 34 s per reader, every result as expected.
--faults takes any of the 33 fault names that python -m mock --help lists: connection
faults (hang, drops in every phase, a reader that never returns after the reboot, power
cycle, busy), certificate and secure-channel faults (rejected host certificate, unsupported
security level, foreign or unparseable reader certificate, session timeout, sequence counter,
bad MAC), unexpected data (garbage instead of a frame, unknown status byte, foreign firmware
string) and configuration faults (no configuration, full store, refused finish, refused
factory reset, slow reboot). tests/test_mock_fleet.py runs the tool against one reader per
fault and checks every result against expected.csv.
To run the fleet on another machine and the tool on this one:
uv run python -m mock --count 1800 --bind auto --jitter 0.3 --bec project.bec
serves the readers on the machine's own address (auto = the address on the default route,
printed at start; --bind 192.168.1.50 names one), ports 2939, 2940, ...; the address column
of readers.csv then carries ip:port. With --addresses 10.10.8.0/21 (a block the machine
owns) every reader gets its own address on port 2939, like real readers. Copy
mock/readers.csv and mock/test_pki/PKI_AUTH_BECU_TEST.zip to the machine with the tool and
select them there. --jitter 0.3 varies the timing of each reader by up to 30 %.
See certs/README.md for the certificate package.
Timing facts for the target readers (Kofax Ethernet card reader, firmware 1096 2.40.03): PKI handshake
about 21 s, upload about 16 ms per configuration byte, reboot about 5 s, one TCP session
per reader at a time. The duration estimate in the window and in the CLI summary uses these
figures.