Skip to content

About

A dual-architecture SCADA simulation system featuring Omron PLC and IoT edge nodes (Raspberry Pi/ESP8266), designed for OT cybersecurity testing, Modbus/TCP integration, and defensive strategy demonstrations.

Resources

Stars

0 stars

Watchers

0 watching

Forks

Latest commit

 

History

23 Commits

Folders and files

Repository files navigation

Mini-SCADA-System

Welcome to the Mini SCADA System repository. This project is divided into two main components:

Please refer to the respective directories for detailed documentation on wiring.

SCADA HMI Overview

SCADA HMI

Setup Node-RED and IoTDB with Docker

  1. Install Docker Make sure Docker and Docker Compose are installed on your machine.
  2. Run Docker Compose Open command prompt in the root of this project and run:
    docker-compose up -d
  3. Access Node-RED Editor Open your browser and navigate to http://localhost:1880.
  4. Access IoTDB You can connect to IoTDB at localhost:6667.

To stop the services, run:

docker-compose down

Maintenance & Restore to Baseline (Penetration Testing)

Since this system is used for penetration testing, components may be compromised, misconfigured, or crashed. Use the following procedures to restore the central servers to a clean baseline.

1. Node-RED (SCADA HMI)

  • Maintenance: Monitor the Node-RED debug tab for unauthorized flow injections or HTTP endpoint abuse.
  • Restore to Baseline:
    1. Open the Node-RED editor at http://localhost:1880.
    2. Select all existing nodes (Ctrl+A) and delete them.
    3. Click Menu > Import and select the clean node-REDFlow.json from either the PLC System or Raspberry System directory, depending on the active test scenario.
    4. Click Deploy to overwrite any compromised flows or rogue UI elements.

2. IoTDB (Historian Database)

  • Maintenance: Use the IoTDB CLI to periodically monitor storage size and active sessions. Because it runs in Docker, use this command to access the CLI:
    docker-compose exec iotdb /iotdb/sbin/start-cli.sh -h 127.0.0.1 -p 6667 -u root -pw root
  • Backup Data: Before a test, back up the database data by creating a copy of the Docker volume or mapping a local host directory to /iotdb/data in your docker-compose.yml and backing up that folder.
  • Restore to Baseline:
    1. Run docker-compose down to stop the database.
    2. Delete the IoTDB data directory or Docker volume to completely wipe the manipulated database state.
    3. Run docker-compose up -d to spin up a fresh, clean instance of IoTDB.
    4. (Optional) If restoring from a specific backup, copy your backed-up data folder into the mapped directory before starting the container.

About